Starway Power Systems Logo

Solar Energy Management System

Solar Energy Management System has a special feature to upgrade any conventional UPS with first priority given to solar. The charger has the intelligence to connect and disconnect the AC mains to the UPS depending upon the battery voltage levels to ensure using solar as primary power and mains only for this emergency.

Technical Specifications

Model NS 3012 SZ NS 3024 SZ NS 6012 SZ NS 6024 SZ
Max. Solar open circuit voltage (Voc) 25 V 40 V 25 V 40 V
Max. Solar panel capacity 360 Wp 720 Wp 720 Wp 1440 Wp
Max. Battery charging current 30 A 30 A 60 A 60 A
Peak charger efficiency 99% 99% 99% 99%
System Voltage (V) 12VDC 24VDC 12VDC 24VDC
Battery full voltage (Solar Charging) 14.5 ± 0.1V 29 ± 0.2V 14.5 ± 0.1V 29 ± 0.2V
Battery Voltage (Mains Disconnect) 14 ± 0.1V 28 ± 0.2V 14 ± 0.1V 28 ± 0.2V
Battery Voltage (Mains Reconnect) 11.3 ± 0.1V 22.6 ± 0.1V 11.3 ± 0.1V 22.6 ± 0.1V
Recommended Battery Capacity 1x200AH 2x200AH 1x400AH 2x400AH
LED Indication Solar Charging, Battery Reverse, Panel Reverse
Physical Termination Solar in & Battery : Terminal block, Mains in : 6A power cord Mains out: 15A power out let
Suitable Motors 612/812/1012
(any 12V sys)
NS 1424
(any 24V sys)
612/812/1012
(any 12V sys)
NS 1424
(any 24V sys)

Solar Power Conditioning Unit | PCU

Technical Specifications

Model NS 512S NS 1024S+ NS 2048S+ NS 3096S+ NS 5120S+
Efficiency (%) 25 V
Transfer Time 15 milliseconds
LCD Indication Status of UPS
Audible Alarm Battery Low, Mode Change Over
Noice Level Less than 50 db
Volts 12 V 24 V 48 V 96 V 120 V
Battery Capacity Recommonded (AH) 300 x 1 300 x 2 300 x 4 200 x 8 150 x 20
Typical low battery alarm voltage (V) 11.0 22.0 44.0 88.0 110.0
Typical Shutdown Battery voltage (V) 10.8 21.6 43.2 86.4 108.0

Intelligent Maximum Power Point Tracking (MPPT) Technology

Model NS 512S NS 1024S+ NS 2048S+ NS 3096S+ NS 5120S+
Battery Charging Current (A) 40 40 40 50 42
Max. Solar Input Power (W) 500 1000 2000 3000 5000
Peak Charger Efficiency 95% 96%
Max. Solar Open Circuit Voltage (V) 85 85 120 240 240

Main Inputs

Model NS 512S NS 1024S+ NS 2048S+ NS 3096S+ NS 5120S+
Normal Input 230V AC, 50 Hz
Input Voltage Lower Cut Off
Computer Mode 165-175 V AC
Normal Mode 110-120 V AC
Input Voltage Higher Cut Off 230-280 V AC (Configurable)
Input Connection 3 Pin Plug (15A)

Output - Inverter Mode

Model NS 512S NS 1024S+ NS 2048S+ NS 3096S+ NS 5120S+
Output Voltage 230V (+/-) 10%
Output Power (VA / Watt) 500/500 1000/1000 2000/2000 2000/3000 5000/5000
Output Frequency (Hz) 49-51
Output Voltage Wave Form Sine Wave
Output Connection 3 Way Terminal Block 15A / 32A
Mains Mode Same as Input

Applications

  • Power backup for your home.
  • Television, fans & Tubelight
  • Domestic Computer & Peripherels
  • Emergency Power Systems
  • Photography
  • Water Pumps and all motor based small applications
  • Professional application where wave form is critical

Applications

  • DSP based control guarantees high reliability
  • Pure sine wave input
  • Compact & light weight
  • Simple & easy installation
  • High efficiency & longer back up time
  • Phase reversal protection
  • Short circuit protection
  • LCD for status monitoring
  • Overload protection & auto recovery
  • Intelligent charging ensures more battery life
  • Normal & Computer mode operation of the UPS
  • Noiceless operation of fans, lamps, and appliances
  • 10% more solar energy is harvested by using MPPT Solar Charger

Applications

Lighting, Battery Over Voltage, Battery Under Voltage, Battery Wire Removal, Output Short Circuit, Overload, Phase Reversal.